| | June 4th, 2004 6:41 am - Doc | [ Bottom ]
|
Manufacturer: |
PowerCom |
|
Author: |
Aleksandr Kagan |

Introduction:
When people buy expensive equipment such
as a $3000 laptop, they want to protect it or want to save data before turning
off their unit. Well PowerCom can provide low cost uninterruptible power
system, which will save the equipment from power surges and addition keep the
equipment going. Not only they will be able to keep the equipment going, they
will also be able to monitor how much power is left from their computer and
even safely browse the Internet through an RJ11/45 cable.
Estimated Price: ~55 USD
Features:
-
UPS self-test (UPS will conduct self-test once switched on each time).
-
Battery auto-charging (If low battery situation is detected, UPS will
automatically charge the battery).
-
Auto restart (It is active when the battery level becomes too low).
-
Overload protection
-
Self-protection (when the unit is switched off, the user must wait 5 seconds
before switching UPS on again).
Specifications:
|
Model
Name: |
KOF-575S |
|
AC INPUT |
|
AC Input
Capacity on Battery: |
120V:
97+/-3V~132+/-3V; 220V:180+/-6V~264+/-6V;
230V:180+/-6V~264+/-6V:240V:194+/-6V~264+/-6V |
|
AC Input
Frequency: |
50 or 60
Hz+/-0.5Hz |
|
AC Input
Transfer: |
2 ~ 4
milliseconds typically |
|
AC OUTPUT |
|
AC Output
Voltage: |
Simulated
sine wave at 120V or 230V +/-10% |
|
AC Output
Frequency: |
50 or 60
Hz +/-5Hz (auto sensing) |
|
PROTECTION |
|
Protection
Spike: |
480
Joules, 2ms |
|
Protection
EMI/RFI: |
10dB at
0.15 MHz, 50 dB at 30 MHz |
|
Protection
Overload: |
UPS
automatic shutdown if overload exceeds 110% nominal at 60 sec and 130%
at 3 sec |
|
Tel/Fax/Modem 10Base-T Cable Port: |
Single
line (2 wires, RJ11) or network (UPT, 11/RJ45) compatible jacks |
|
Short
Circuit: |
UPS output
cut off immediately or input circuit break protection |
|
BATTERY |
|
Battery
Type: |
HC1221W |
|
Battery
Typical: |
4 Hours |
|
Battery
Protection: |
Automatic self-test & discharge protection, replace battery indicator |
|
Battery
Run Time: |
15 - 28
minutes |
|
PHYSICAL |
|
Physical
Weight: |
5 kgs / 11
lbs | Shipping: 5.7kbs / 12.56 lbs |
|
Physical
Dimensions: |
278x124x118mm |
|
Physical
Input Inlet: |
C.P.:
Continental plug, E.P.: Edison Plug, A.P. Australia plug |
|
Physical
Receptacles: |
NEMA 5-15A
(120V) / IEC 320 female appliance coupler (230V), 3 for surge European
sockets / other countries sockets, 2 for UPS, 2 for surge |
|
ALARM |
|
Alarm
Battery Backup: |
Slow
beeping sound (about 0.2 Hz) |
|
Alarm
Battery Low: |
Rapid
beeping sound (about 1 Hz) |
|
INTERFACE |
|
RS232
Interface: |
Bidirectional communication port |
|
ENVIRONMENT |
|
Environment Ambient: |
3,500
meters max. elevation, 0-95% humidity non-condensing, 0-40 deg c |
|
Environment Audible: |
<40dBA (1
meter from surface) |
|
ShowOrder:
|
0 |
Package Contents:
-
UPS Unit -
KOF-575S
-
RJ11 Telephone
Cable
-
Serial Cable
-
UPSMON 2.72 CD
-
User guide
| |